Linux-2.6.12-rc2
[linux-flexiantxendom0-natty.git] / drivers / mtd / nand / Kconfig
1 # drivers/mtd/nand/Kconfig
2 # $Id: Kconfig,v 1.26 2005/01/05 12:42:24 dwmw2 Exp $
3
4 menu "NAND Flash Device Drivers"
5         depends on MTD!=n
6
7 config MTD_NAND
8         tristate "NAND Device Support"
9         depends on MTD
10         select MTD_NAND_IDS
11         help
12           This enables support for accessing all type of NAND flash
13           devices. For further information see
14           <http://www.linux-mtd.infradead.org/tech/nand.html>.
15
16 config MTD_NAND_VERIFY_WRITE
17         bool "Verify NAND page writes"
18         depends on MTD_NAND
19         help
20           This adds an extra check when data is written to the flash. The
21           NAND flash device internally checks only bits transitioning
22           from 1 to 0. There is a rare possibility that even though the
23           device thinks the write was successful, a bit could have been
24           flipped accidentaly due to device wear or something else.
25
26 config MTD_NAND_AUTCPU12
27         tristate "SmartMediaCard on autronix autcpu12 board"
28         depends on ARM && MTD_NAND && ARCH_AUTCPU12
29         help
30           This enables the driver for the autronix autcpu12 board to 
31           access the SmartMediaCard.
32
33 config MTD_NAND_EDB7312
34         tristate "Support for Cirrus Logic EBD7312 evaluation board"
35         depends on ARM && MTD_NAND && ARCH_EDB7312
36         help
37           This enables the driver for the Cirrus Logic EBD7312 evaluation 
38           board to access the onboard NAND Flash.
39
40 config MTD_NAND_H1900
41         tristate "iPAQ H1900 flash"
42         depends on ARM && MTD_NAND && ARCH_PXA && MTD_PARTITIONS
43         help
44           This enables the driver for the iPAQ h1900 flash.
45
46 config MTD_NAND_SPIA
47         tristate "NAND Flash device on SPIA board"
48         depends on ARM && ARCH_P720T && MTD_NAND
49         help
50           If you had to ask, you don't have one. Say 'N'.
51
52 config MTD_NAND_TOTO
53         tristate "NAND Flash device on TOTO board"
54         depends on ARM && ARCH_OMAP && MTD_NAND
55         help
56           Support for NAND flash on Texas Instruments Toto platform.
57
58 config MTD_NAND_IDS
59         tristate
60
61 config MTD_NAND_TX4925NDFMC
62         tristate "SmartMedia Card on Toshiba RBTX4925 reference board"
63         depends on TOSHIBA_RBTX4925 && MTD_NAND && TOSHIBA_RBTX4925_MPLEX_NAND
64         help
65           This enables the driver for the NAND flash device found on the
66           Toshiba RBTX4925 reference board, which is a SmartMediaCard.
67
68 config MTD_NAND_TX4938NDFMC
69         tristate "NAND Flash device on Toshiba RBTX4938 reference board"
70         depends on TOSHIBA_RBTX4938 && MTD_NAND && TOSHIBA_RBTX4938_MPLEX_NAND 
71         help
72           This enables the driver for the NAND flash device found on the
73           Toshiba RBTX4938 reference board.
74
75 config MTD_NAND_AU1550
76         tristate "Au1550 NAND support"
77         depends on SOC_AU1550 && MTD_NAND
78         help
79           This enables the driver for the NAND flash controller on the
80           AMD/Alchemy 1550 SOC.
81
82 config MTD_NAND_RTC_FROM4
83         tristate "Renesas Flash ROM 4-slot interface board (FROM_BOARD4)"
84         depends on MTD_NAND && SH_SOLUTION_ENGINE
85         select REED_SOLOMON
86         select REED_SOLOMON_DEC8
87         help
88           This enables the driver for the Renesas Technology AG-AND 
89           flash interface board (FROM_BOARD4)
90
91 config MTD_NAND_PPCHAMELEONEVB
92         tristate "NAND Flash device on PPChameleonEVB board"
93         depends on PPCHAMELEONEVB && MTD_NAND
94         help
95           This enables the NAND flash driver on the PPChameleon EVB Board.
96
97 config MTD_NAND_S3C2410
98         tristate "NAND Flash support for S3C2410 SoC"
99         depends on ARCH_S3C2410 && MTD_NAND
100         help
101           This enables the NAND flash controller on the S3C2410.
102
103           No board specfic support is done by this driver, each board
104           must advertise a platform_device for the driver to attach. 
105
106 config MTD_NAND_S3C2410_DEBUG
107         bool "S3C2410 NAND driver debug"
108         depends on MTD_NAND_S3C2410
109         help
110           Enable debugging of the S3C2410 NAND driver
111
112 config MTD_NAND_S3C2410_HWECC
113         bool "S3C2410 NAND Hardware ECC"
114         depends on MTD_NAND_S3C2410
115         help
116           Enable the use of the S3C2410's internal ECC generator when
117           using NAND. Early versions of the chip have had problems with
118           incorrect ECC generation, and if using these, the default of
119           software ECC is preferable.
120
121           If you lay down a device with the hardware ECC, then you will
122           currently not be able to switch to software, as there is no
123           implementation for ECC method used by the S3C2410
124
125 config MTD_NAND_DISKONCHIP
126         tristate "DiskOnChip 2000, Millennium and Millennium Plus (NAND reimplementation) (EXPERIMENTAL)"
127         depends on MTD_NAND && EXPERIMENTAL
128         select REED_SOLOMON
129         select REED_SOLOMON_DEC16
130         help
131           This is a reimplementation of M-Systems DiskOnChip 2000,
132           Millennium and Millennium Plus as a standard NAND device driver,
133           as opposed to the earlier self-contained MTD device drivers.
134           This should enable, among other things, proper JFFS2 operation on
135           these devices.
136
137 config MTD_NAND_DISKONCHIP_PROBE_ADVANCED
138         bool "Advanced detection options for DiskOnChip"
139         depends on MTD_NAND_DISKONCHIP
140         help
141           This option allows you to specify nonstandard address at which to
142           probe for a DiskOnChip, or to change the detection options.  You
143           are unlikely to need any of this unless you are using LinuxBIOS.
144           Say 'N'.
145
146 config MTD_NAND_DISKONCHIP_PROBE_ADDRESS
147         hex "Physical address of DiskOnChip" if MTD_NAND_DISKONCHIP_PROBE_ADVANCED
148         depends on MTD_NAND_DISKONCHIP
149         default "0"
150         ---help---
151         By default, the probe for DiskOnChip devices will look for a
152         DiskOnChip at every multiple of 0x2000 between 0xC8000 and 0xEE000.
153         This option allows you to specify a single address at which to probe
154         for the device, which is useful if you have other devices in that
155         range which get upset when they are probed.
156
157         (Note that on PowerPC, the normal probe will only check at
158         0xE4000000.)
159
160         Normally, you should leave this set to zero, to allow the probe at
161         the normal addresses.
162
163 config MTD_NAND_DISKONCHIP_PROBE_HIGH
164         bool "Probe high addresses"
165         depends on MTD_NAND_DISKONCHIP_PROBE_ADVANCED
166         help
167           By default, the probe for DiskOnChip devices will look for a
168           DiskOnChip at every multiple of 0x2000 between 0xC8000 and 0xEE000.
169           This option changes to make it probe between 0xFFFC8000 and
170           0xFFFEE000.  Unless you are using LinuxBIOS, this is unlikely to be
171           useful to you.  Say 'N'.
172
173 config MTD_NAND_DISKONCHIP_BBTWRITE
174         bool "Allow BBT writes on DiskOnChip Millennium and 2000TSOP"
175         depends on MTD_NAND_DISKONCHIP
176         help
177           On DiskOnChip devices shipped with the INFTL filesystem (Millennium
178           and 2000 TSOP/Alon), Linux reserves some space at the end of the
179           device for the Bad Block Table (BBT).  If you have existing INFTL
180           data on your device (created by non-Linux tools such as M-Systems'
181           DOS drivers), your data might overlap the area Linux wants to use for
182           the BBT.  If this is a concern for you, leave this option disabled and
183           Linux will not write BBT data into this area.
184           The downside of leaving this option disabled is that if bad blocks
185           are detected by Linux, they will not be recorded in the BBT, which
186           could cause future problems.
187           Once you enable this option, new filesystems (INFTL or others, created
188           in Linux or other operating systems) will not use the reserved area.
189           The only reason not to enable this option is to prevent damage to
190           preexisting filesystems.
191           Even if you leave this disabled, you can enable BBT writes at module
192           load time (assuming you build diskonchip as a module) with the module
193           parameter "inftl_bbt_write=1".
194           
195  config MTD_NAND_SHARPSL
196         bool "Support for NAND Flash on Sharp SL Series (C7xx + others)"
197         depends on MTD_NAND     && ARCH_PXA
198  
199  config MTD_NAND_NANDSIM
200         bool "Support for NAND Flash Simulator"
201         depends on MTD_NAND && MTD_PARTITIONS
202
203         help
204           The simulator may simulate verious NAND flash chips for the
205           MTD nand layer.
206  
207 endmenu